Vacuum Induction Furnace

1) Anhydrous cold-dissolving electrode device.
In order to avoid a structure in which coolant is circulated inside the vacuum chamber as much as possible,
An electrode, which is a high frequency output transmission device, is used as an anhydrous cooling electrode device.
1.1) Rated input: 1 phase 350 - 550 V 75 KW
1.2) Cooling method: Air cooling and forced circulation gas cooling method
1.3) Rated output frequency: 20-30 KHZ
1.4) Material used: High purity anaerobic.
1.5) Circular gas quantity: 10LPM/5Kg/㎠
1.6) Input terminal : Compatibility with output terminal of current conversion device of low pressure and high current
1.7) Appearance dimensions: 2250 × 300 L
1.8) Weight: 30kg
2) Current conversion system.
Existing high-frequency facilities are high-voltage and low-current facilities that utilize cold crumbles.
It₩s not suitable for self-support, so it doesn₩t affect existing facilities.
A TransFormer that generates a low voltage and high current required to achieve the desired purpose.
It is connected in series and driven.
2.1) Rated input: 1 phase 600 - 800V 75KW
2.2) Rated output: 1 phase 350 - 550 V 3000 A
2.3) Cooling method: Air-cooled and forced water-
2.4) Rated output frequency: 20-30 KHZ
2.5) Material used: High purity anaerobic
2.6) Applied core: Molding ferrite powder core
2.7) Appearance dimension : 350 x 350 x 350H
2.8) Weight: 80kg
3) COLD CRUCIBLE (for CU500g)
In order to dissolve high purity metal, cold crumbles are used without a separate crucible.
Therefore, as a metal crucible for self-support dissolution, a high purity water-cooled metal tube is used.
It is a structure that easily affects a metal with a high frequency magnetic field.
3.1) Material: High purity anaerobic.
3.2) Rated capacity: CU 500g.
3.3) Structure: It is a circular water-cooled metal tube structure, and the metal tube spacing is 0.5 mm.
3.4) Appearance dimensions: ∅70 x 120H
3.5) Weight: 20kg.